Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Eur Heart J Cardiovasc Imaging ; 24(8): 1052-1061, 2023 07 24.
Artículo en Inglés | MEDLINE | ID: mdl-36752044

RESUMEN

AIMS: The prognostic impact of flow trajectories according to stroke volume index (SVi) and transvalvular flow rate (FR) in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) remains poorly assessed. We evaluated and compared SVi and FR prior and after TAVR for severe AS. METHODS AND RESULTS: Patients were categorized according to SVi (<35 mL/m2) and FR (<200 mL/s). The association of pre- and post-TAVR SVi and FR with all-cause mortality up to 3 years was assessed with multivariable Cox regression models. Among 980 patients with pre-TAVR flow assessment, SVi was reduced in 41.3% and FR in 48.1%. Baseline flow status was not an independent mortality predictor [SVi: hazard ratio (HR) 1.22, 95% confidence interval (CI) 0.85-1.82, FR: HR 0.78, 95% CI 0.48-1.27]. Among 731 patients undergoing early (5 days, interquartile range 2-29) post-TAVR flow assessment, SVi recovered in 40.1% and FR in 49.0% patients with baseline low flow. Reduced FR following TAVR was an independent predictor of mortality (HR 1.67, 95% CI 1.02-2.74), whereas SVi was not (HR 0.97, 95% CI 0.53-1.78). Three-year estimated mortality in patients with recovered FR was lower than that in patients with reduced FR (13.3 vs. 37.7% vs, P = 0.003) and similar to that in patients with normal baseline FR (P = 0.317). CONCLUSION: Baseline flow status was not an independent predictor of mid-term mortality among all-comers with severe AS undergoing TAVR. Flow recovery early after TAVR was frequent. Post-TAVR FR, but not SVi, was independently associated with mid-term all-cause mortality. By impacting flow status, AV replacement modifies the association of flow status with outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Volumen Sistólico , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Factores de Riesgo , Estudios Retrospectivos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Índice de Severidad de la Enfermedad
2.
J Cardiovasc Echogr ; 31(2): 102-103, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34485037

RESUMEN

We report the challenging case of percutaneous treatment of early recurrent mitral regurgitation after Alfieri edge-to-edge surgical procedure.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...